Research article

Electric Transmission Tower Corrosion Assessment Using Analytic Hierarchy Process and Health Index

Aina Shazwana Mohd Izhar, Nor Hazwani Nor Khalid, Fathoni Usman, Mohd Supian Abu Bakar, Nur Fadilah Adriyanshah and Hakim Zahari

https://doi.org/10.47836/pjst.32.4.21
KeywordsAnalytical hierarchy process, corrosion assessment, energy, health index, transmission tower
Article content

Abstract

A transmission tower is one of the components in power infrastructure supporting overhead power lines (OHL). Electrical components, structural, and environmental factors are classified as the primary concern as they can cause catastrophic failure in transmission lines. Transmission towers are in various environments, such as coastal and industrial areas, with different atmospheric corrosion levels due to various corrosive pollutants. For maintenance planning, it is essential to consider the effects of corrosion on towers by physical evaluation influenced by atmospheric corrosion. The physical evaluation of each element uses a scoring or rating method ranging from one to five. The Analytic Hierarchy Process (AHP) and Health Index (HI) are used to evaluate the overall condition of the towers. The study discovered that soil corrosivity in coastal areas is high, and atmospheric corrosion is due to chloride content. Although the pollutants in those areas are high and corrosive, the physical evaluation found that most industrial, coastal, and road towers are in good condition at a rating of 4 and 5. The HI result is the dominance of 71% to 85%, which indicates that the towers are in good health.
Supporting literature

References

  1. Adriyanshah, N. F., Khalid, N. H. N., Usman, F., Izhar, A. S. M., Jawas, J. A., & Jalal, W. N. W. (2022). Development of corrosion hazard map in peninsular Malaysia using inverse distance weighting (IDW) interpolation. In M. Awang, L. Ling & S. S. Emamian (Eds.), Advances in Civil Engineering Materials (pp. 225-233). Springer. https://doi.org/10.1007/978-981-16-8667-2_24
  2. Arroyave, C., & Morcillo, M. (1995). The effect of nitrogen corrosion oxides in atmospheric. Corrosion Science, 37(2), 293–305. https://doi.org/10.1016/0010-938X(94)00136-T
  3. Beynon, M. (2002). DS / AHP method : A mathematical analysis, including an understanding of uncertainty. European Journal of Operational Research, 140(1), 148–164. https://doi.org/10.1016/S0377-2217(01)00230-2
  4. Cardenas, L. A., Alvarez, D. L., Garcia, S. R., & Herrera, F. A. (2019, December 4-6). Overhead lines assessment using health index. [Paper presentation]. FISE-IEEE/CIGRE Conference - Living the energy Transition (FISE/CIGRE), Medellin, Colombi. https://doi.org/10.1109/FISECIGRE48012.2019.8984959
  5. Chitpong, J., Suwanasri, C., & Suwanasri, T. (2016, June 28 - July 1). Evaluation criteria for condition and importance assessment of high voltage transmission line. [Paper presentation]. 13th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON), Chiang Mai, Thailang. https://doi.org/10.1109/ECTICon.2016.7561237
  6. Corvo, F., Perez, T., Dzib, L. R., Martin, Y., Castañeda, A., Gonzalez, E., & Perez, J. (2008). Outdoor-indoor corrosion of metals in tropical coastal atmospheres. Corrosion Science, 50(1), 220–230. https://doi.org/10.1016/j.corsci.2007.06.011
  7. Daneshmand, S. V., Heydari, H., & Shakeri, S. (2011). Multicriteria optimal winding scheme in HTS transformers by analytical hierarchy process. IEEE Transactions on Applied Superconductivity, 21(1), 2–12. https://doi.org/10.1109/TASC.2010.2089051
  8. Eyre-Walker, R., Howartht, G., Ahmedv, R., & Lewin, J. (2014, November 27-28). Application of advanced condition assessment and asset management techniques on steel tower overhead line electricity networks. [Paper presentation]. Asset Management Conference, London, United Kingdom. https://doi.org/10.1049/cp.2014.1047
  9. Fathoni, U., Zakaria, C. M., & Rohayu, C. O. (2013). Development of corrosion risk map for Peninsular Malaysia using climatic and air pollution data. IOP Conference Series: Earth and Environmental Science, 16(1), Article 012088. https://doi.org/10.1088/1755-1315/16/1/012088
  10. Feliu, S., Morcillo, M., & Chico, B. (1999). Effect of distance from sea on atmospheric corrosion rate. Corrosion, 55(9), 883–891. https://doi.org/10.5006/1.3284045
  11. Frost & Sullivan. (2021, August 19). Rising demand for energy efficiency and sustainability boosts the southeast asian integrated facilities management market. https://www.frost.com/news/press-releases/rising-demand-for-energy-efficiency-and-sustainability-boosts-the-southeast-asian-integrated-facilities-management-market/
  12. Haema, J., & Phadungthin, R. (2012, September 18-20). Condition assessment of the health index for power transformer. [Paper presentation] Power Engineering and Automation Conference, Wuhan, China. https://doi.org/10.1109/PEAM.2012.6612413
  13. Hashim, R., Usman, F., & Baharuddin, I. N. Z. (2019). Determining health index of transmission line asset using condition-based method. Resources, 8(2), 80. https://doi.org/10.3390/resources8020080
  14. Hjartarson, T., Jesus, B., Hughes, D. T., & Godfrey, R. M. (2003, September 7-12). Developement of health indices for asset condition assessment. [Paper presentation]. IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495), Dallas, USA. https://doi.org/10.1109/TDC.2003.1335332
  15. Huang, R., An, L., Zhang, R., Wu, J., & Liang, Y. (2018). Research on condition assessment method of transmission tower under the action of strong wind. IOP Conference Series: Materials Science and Engineering, 322(7), Article 072054. https://doi.org/10.1088/1757-899X/322/7/072054
  16. Irfan, J., & Handika, P. (2019, October 10-11). Comprehensive calculation of overhead transmission line health index. [Paper presentation]. 11th International Conference on Information Technology and Electrical Engineering (ICITEE), Pattaya, Thailand. https://doi.org/10.1109/ICITEED.2019.8929988
  17. Jyothi, B., & Mahesh, S. (2017). Design transmission tower and its foundation. International Journal of Scientific Engineering and Technology Research, 6(6), 1008–1014.
  18. Krishnasamy, R., Shyamala, G., Johnson, S. C., Sabarinathan, K., Sakthivel, S. M., & Rajesh, K. (2020). Performance management of transmission line tower foundations against corrosion by non destructive testing. International Journal of Engineering and Advanced Technology, 9(3), 443–447. https://doi.org/10.35940/ijeat.c4731.029320
  19. Kumar, V., Sharma, N., Tiwari, S. K., & Kango, S. (2020). Atmospheric corrosion of materials and their effects on mechanical properties: A brief review. Materials Today: Proceedings, 44, 4677–4681. https://doi.org/10.1016/j.matpr.2020.10.939
  20. Kwan, M. S., Tangang, F. T., & Juneng, L. (2013). Projected changes of future climate extremes in Malaysia. Sains Malaysiana, 42(8), 1051–1058.
  21. Lin, Z. C., & Yang, C. B. (1996). Evaluation of machine selection by the AHP method. Journal of Material Processing Energy, 57(3–4), 253–258. https://doi.org/10.1016/0924-0136(95)02076-4
  22. Manninen, H., Ramlal, C. J., Singh, A., Rocke, S., Kilter, J., & Landsberg, M. (2021). Toward automatic condition assessment of high-voltage transmission infrastructure using deep learning techniques. International Journal of Electrical Power and Energy Systems, 128, Article 106726. https://doi.org/10.1016/j.ijepes.2020.106726
  23. Naranpanawe, L., Ma, H., Saha, T. K., Lee, C., & Ghosal, A. (2020). A practical health index for overhead conductors : Experience from Australian distribution networks. IEEE Access, 8, 218863–218873. https://doi.org/10.1109/ACCESS.2020.3042486
  24. Pongsaksawad, W., Klomjit, P., Khamsuk, P., Sorachot, S., Pålsson, N. S., & Viyanit, E. (2021). Chloride distribution model and corrosion map of structural steels for tropical climate in Thailand. Science of the Total Environment, 787, Article 147465. https://doi.org/10.1016/j.scitotenv.2021.147465
  25. Rajesh, G., & Malliga, P. (2013). Supplier selection based on AHP QFD methodology. Procedia Engineering, 64, 1283–1292. https://doi.org/10.1016/j.proeng.2013.09.209
  26. Ricci, G., Bertella, R., Prato, S., & Zippo, M. (2018, October 3-5). A.RI.EL: A structural integrity condition based method for renewal assessment of pylons in overhead transmission lines. [Paper presentation]. AEIT International Annual Conference, Bari, Italy.
  27. Rodger, J., Bartlett, S., & Atrens, A. (2017). Corrosion of the galvanising of galvanised-Steel electricity transmission towers. Materials and Corrosion, 68(8), 902–910. https://doi.org/10.1002/maco.201609351
  28. Saaty, T. L. (2008). Decision making with the analytic hierarchy process. International Journal of Services Sciences, 1(1), 83–98. https://doi.org/10.1504/IJSSCI.2008.017590
  29. Saaty, T. L. (1977). A scaling method for priorities in hierarchical structures. Journal of Mathematical Psychology, 15(3), 234–281. https://doi.org/10.1016/0022-2496(77)90033-5
  30. Sing, L. K., Yahaya, N., Othman, S. R., Fariza, S. N., & Noor, N. M. (2013). The relationship between soil resistivity and corrosion growth in tropical region. Journal of Corrosion Science and Engineering, 16, 1–11.
  31. Soufeiani, L., Foliente, G., Nguyen, K. T. Q., & Nicolas, R. S. (2020). Corrosion protection of steel elements in façade systems – A review. Journal of Building Engineering, 32, Article 101759. https://doi.org/10.1016/j.jobe.2020.101759
  32. Syed, S. (2006). Atmospheric corrosion of materials. Emirates Journal for Engineering Research, 11(1), 1–24.
  33. Tanaka, H., Tsukao, S., Yamashita, D., Niimura, T., & Yokoyama, R. (2010). Multiple criteria assessment of substation conditions by pair-wise comparison of analytical hierarchy process. IEEE Transactions on Power Delivery, 25(4), 3017–3023. https://doi.org/10.1109/TPWRD.2010.2048437
  34. Tang, K. H. D. (2019). Climate change in Malaysia: Trends, contributors, impacts, mitigation and adaptations. Science of the Total Environment, 650, 1858–1871. https://doi.org/10.1016/j.scitotenv.2018.09.316
  35. Triantaphyllou, E., & Mann, S. H. (1995). Using the analytic hierarchy process for decision making in engineering applications: Some challenges. International Journal of Industrial Engineering: Applications and Practice, 2(1), 35–44.
  36. Tsimberg, Y., Lotho, K., Dimnik, C., Wrathall, N., & Mogilevsky, A. (2014, April 14-17). Determining transmission line conductor condition and remaining life. [Paper presentation]. IEEE PES T&D Conference and Exposition, Chicago, USA. https://doi.org/10.1109/tdc.2014.6863242
  37. Usman, F., Khalid, N. H. N., Omar, R. C., & Jawas, M. J. A. (2021). Atmospheric corrosion map for service life prediction of lattice steel tower using air pollution data and meteorological data. AIP Conference Proceedings, 2339(1), Article 020189. https://doi.org/10.1063/5.0044393
  38. Usman, F., & Khalid, N. H. N. (2021). Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data. E3S Web of Conferences, 325, Article 01011. https://doi.org/10.1051/e3sconf/202132501011
  39. Usman, F., & Resdiansyah, M. (2008, June 16-20). Service life prediction of building components. International Conference on Construction and Building Technology (ICCBT), Kuala Lumpur, Malaysia
  40. Van-Der-Wal, A., Ross, A. A. H. J., & Kema, T. D. C. (2004). Condition assessment of overhead lines (Report No. B2-204).CIGRE. https://www.e-cigre.org/publications/detail/b2-204-2004-condition- assessment-of-overhead-lines.html
  41. Velásquez, R. M. A., & Lara, J. V. M. (2018, September 19-21). Methodology for overhead line conductor remaining life aging infrastructure and asset management. [Paper presentation]. IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D-LA), Lima, Peru. https://doi.org/10.1109/TDC-LA.2018.8511752.
  42. Wang, J., Liu, P., Ren, K., Wang, X., & Xu, S. (2022). Corrosion of steel materials in four environmental conditions. Journal of Physics: Conference Series, 2390, Article 012002. https://doi.org/10.1088/1742-6596/2390/1/012002
  43. Waters, F. O. (1952). Soil resistivity measurements for corrosion control. Corrosion- National Association of Corrosion Engineers, 8(12), 407–409. https://doi.org/10.5006/0010-9312-8.12.407
  44. Wuller, A. I., & Pharmatrisanti, A. (2012, September 23-27). Transmission line assessment. [Paper presentation]. IEEE International Conference on Condition Monitoring and Diagnosis, Bali Indonesia. https://doi.org/10.1109/CMD.2012.6416418
  45. Zhang, D., Li, W., & Xiong, X. (2014). Overhead line preventive maintenance strategy based on condition monitoring and system reliability assessment. IEEE Transactions on Power Systems, 29(4), 1839–1846. https://doi.org/10.1109/TPWRS.2013.2295379
  46. Zhang, T., Liu, L., Wiliem, A., Connor, S., Ilich, Z., Van Der Draai, E., & Lovell, B. (2019, December 2-4). Deep corrosion assessment for electrical transmission towers. [Paper presentation]. Digital Image Computing: Techniques and Applications (DICTA), Perth, Australia. https://doi.org/10.1109/DICTA47822.2019.8945905